HYDRAcap40 ACS Ultrafiltration
HYDRAcap40 ACS Ultrafiltration

HYDRAcap40 ACS Ultrafiltration

Other water filters

Model Number: HYDRAcap40 ACS HYDRAcap40-DWI

Filtrate Flow : 7.7 – 18.9 gpm (1.8 – 4.3 m3 /h)

Configuration : Capillary Ultrafiltration Module

Membrane Polymer : Hydrophilic Polyethersulfone

Nominal Membrane Area : 320 ft2 (30 m2 )

Pore size : 0.02 micron

Get Quotation

Product Details

HYDRAcap40 is used to treat surface water, groundwater, seawater and wastewaters as either primary treatment or as pretreatment to reverse osmosis (RO) and nanofiltration (NF)

Application Data

Typical Filtrate Flux Range: 35 – 85 gfd (59 – 145 l/m2/h)

Maximum Applied Feed Pressure: 73 psig (5 bar) 

Maximum Transmembrane Pressure 20 psig (1.4 bar)

Maximum Backwash Transmembrane Pressure: 20 psig (1.4 bar)

Instantaneous Chlorine Tolerance: 100 ppm

Instantaneous Hydrogen Peroxide Tolerance: 200 ppm

Maximum Chlorine Exposure: 200,000 ppm-hrs

Maximum Instantaneous Feed Turbidity: 100 NTU

Maximum Operating Temperature: 104 °F (40 °C)

pH Operating Range: 4.0 - 10.0

Cleaning pH Range: 1.5 – 13.0

Operating Mode: Inside to Outside Filtration  Direct flow or Crossflow