Other water filters
Model Number: HYDRAcap-40
Filtrate Flow : 7.7 – 18.9 gpm (1.8 – 4.3 m 3 /h)
Filtrate Turbidity : ≤ 0.07 NTU
Virus removal : ≥ 4 log
Nominal Membrane Area : 320 ft2 (30 m 2 )
Fiber Dimensions : ID 0.031” (0.8 mm), OD 0.055” (1.4 mm)
Pore size : 0.02 micron
HYDRAcap-40 is used to treat surface water, groundwater, seawater and wastewaters as either primary treatment or as pretreatment to reverse osmosis (RO) and nanofiltration (NF).
Application Data
Typical Filtrate Flux Range: 35 – 85 gfd (59 – 145 l/m2/h)
Maximum Applied Feed Pressure: 73 psig (5 bar)
Maximum Transmembrane Pressure 20 psig (1.4 bar)
Maximum Backwash Transmembrane Pressure: 20 psig (1.4 bar)
Instantaneous Chlorine Tolerance: 100 ppm
Instantaneous Hydrogen Peroxide Tolerance: 200 ppm
Maximum Chlorine Exposure: 200,000 ppm-hrs
Maximum Instantaneous Feed Turbidity: 100 NTU
Maximum Operating Temperature: 104 F (40 C)
pH Operating Range: 4.0 - 10.0
Cleaning pH Range: 1.5 – 13.0
Operating Mode: Inside to Outside Filtration Direct flow or Crossflow