ESPA2-LD RO membranes are designed to filter brackish water while maximizing energy savings and includes low fouling technology. The RO elements in these membranes are of the highest standard, can be used in primary or pretreatment, and are suited for global municipalities and industries.
Product Use and Restrictions
Maximum Applied Pressure: 600 psig (4.14 MPa)
Maximum Chlorine Concentration: < 0.1 ppm
Maximum Operating Temperature: 113 °F (45 °C)
pH Range, Continuous (Cleaning): 2-10.6 (1-12)
Maximum Feedwater Turbidity: 1.0 NTU
Maximum Feedwater SDI (15 mins): 5.0
Maximum Feed Flow: 85 gpm (19.3 m3/h)
Minimum Brine Flow: 12 gpm 2.7 m3/h)
Maximum Pressure Drop for Each Element: 15 psi (0.10 MPa)